Introduction
Fractures of the calcaneus still remain some of the most challenging injuries that an orthopedic surgeon should manage. The difficulties about these fractures arise from the specific anatomy of the region, from the unique shape and morphology of the bone, and from the mechanism of the injury (in most cases high energy trauma). Despite the progress of the medical implants that can be used for fracture fixation in the last decade there are a lot of controversies, regarding the best option.
Aim
The aim of the study is to present our experience with the use of cannulated screws for fixation of dislocated fractures of os calcis.
Materials and Methods
Twenty patients with dislocated fractures of os calcis using cannulated screws for fixation were operated on for a period of two years (2017-2018). The classifications used in the study included: the Essex-Lopresti x-ray classification modified by Stulik and Stehlik and the CT classification of Sanders. Two of the patients were with dislocated extraarticular fractures of tuber calcanei, three patients with `extreme beak` type fractures, the remaining 15 patients were with intraarticular fractures with more than 2 mm step off in the subtalar joint: 9 patients with tongue type and 5 patients with joint depression type. Gender distribution: 18 men, 2 women.
Results
Evaluation of the results was made by using the Maryland Foot Score. Satisfaction from the treatment was graded using the Visual Analogue Scale (VAS) score (mean 7,5). The reduction is evaluated by measurement of the angle of Gissane, Bohler and Preis pre- and postoperatively. Assessment of the calcaneal height, length and width was initiated on lateral, axial and Broden views.
Conclusion
Fixation of displaced calcaneal fractures by cannulated screw is effective and reliable method. These screws are introduced by stab incisions which leads to minimal soft tissue dissection in such complex area of the hindfoot. It is an enormous advantage for fracture healing and reduces the percentage of possible complications.
Palmer I. The mechanism and treatment of fractures of the calcaneus. Open reduction with use of cancellous grafts. J Bone Joint Surg Am. 1948; 30A(1):2-8.
Buckley R, Tough S, McCormack R, Pate G, Leighton R, Petrie D, et al. Operative compared with nonoperative treatment of displaced intra-articular calcaneal fractures: a prospective, randomized, controlled multicenter trial. J Bone Joint Surg Am. 2002; 84(10):1733-44.
Benirske SK, Sangeorzgan BJ. Extensive intraarticular fractures of the foot. Surgical management of calcaneal fractures. Clin. Orthop. 1993; 292:128-34.
Forgon M: Closed reduction and percutaneous osteosynthesis: Technique and results in 265 calcaneal fractures. In: Tscherne H, Schatzker J, eds. Major fractures of the pilon, the talus, and the calcaneus. New York: Springer- Verlag; 1993. p. 207-13.
Stulik J, Stehlik J, Rysavy M, Wozniak A. Minimally-invasive treatment of intra-articular fractures of the calcaneum. J Bone Joint Surg Br. 2006;88(12):1634-41. doi: 10.1302/0301-620X.88B12.17379.
Sanders R, Fortin P, Dipasquale T. Operative treatment of 120 displaced intraarticular calcaneal fractures. Results using a prognostic computed tomography scan classification. Clin Orthop Relat Res. 1993;(290):87-95.
Bohler L. Diagnosis, pathology and treatment of fractures of the os calcis, J Bone Joint Surg Am. 1931; 13(1):75-89.
Essex - Lopresti P. The mechanism, reduction technique and results in fractures of the os calcis; British J Surg. 1952; 39(157):395-419.
Broden B. Roentgen examination of the subtaliod joint in fractures of the calcaneus. Acta Radiol. 1949;31(1):85-91.
Schepers T, Schipper IB, Vogels LM, Ginai AZ, Mulder PG, Heetveld MJ, et al. Percutaneous treatment of displaced intra-articular calcaneal fractures. J Orthop Sci. 2007; 12(1):22-7. doi: 10.1007/s00776-006-1076-z.
Patel N, Bhavsar N, Lil N. Percutaneous fixation of Calcaneum fractures. GCSMC J Med Sci. 2014;3(1):31-4.
Qiang M, Chen Y, Zhang K, Li H, Dai H. Effect of sustentaculum screw placement on outcomes of intraarticular calcaneal fracture osteosynthesis: A prospective cohort study using 3D CT. Int J Surg. 2015;19:72-7. doi: 10.1016/j.ijsu.2015.05.011.
Wang C, Huang D, Ma X, Wang X, Huang J, Zhang C, et al. Sustentacular screw placement with guidance during ORIF of calcaneal fracture: an anatomical specimen study. J Orthop Surg Res. 2017;12(1):78. doi: 10.1186/s13018-017-0580-5.
Labronici1 PJ, Pereira DN, Pilar M, Franco JS, Serra MD, Cohen JC, et al. Safe localization for placement of percutaneous pins in the calcaneus. Rev Bras Ortop. 2012;47(4):455-9. doi: 10.1016/S2255-4971(15)30128-2
Phisitkul P, Sullivan J, Goetz J, Marsh J. Maximizing safety in screw placement for posterior facet fixation in calcaneus fractures: A cadaveric radio-anatomical study. Foot Ankle Int. 2013;34(9):1279-85. doi: 10.1177/1071100713487182.
Carr J, Tigges R, Wayne J, Mark E. Internal fixation of experimental intraarticular calcaneal fractures: A biomechanical analysis of two fixation methods. J Orthop Trauma. 1997;11(6):425-8; discussion 428-9.
Smerek JP, Kadakia A, Belkoff SM, Knight TA, Myerson MS, Jeng CL. Percutaneous screw configuration versus perimeter plating of calcaneus fractures: A cadaver study. Foot Ankle Int. 2008;29(9):931-5. doi: 10.3113/FAI.2008.0931.
Ming N, Mei J, Lil K, Niu W, Zhang M. The primary stability of different implants for intraA‘articular calcaneal fractures: an in vitro study. Biomed Eng Online. 2018;17(1):50. doi: 10.1186/s12938-018-0484-6.
Rausch S, Klos K, Wolf U, Gras M, Simons P, Gueorguiev B, et al. A biomechanical comparison of fixed angle locking compression plate osteosynthesis and cement augmented screw osteosynthesis in the management of intra articular calcaneal fractures; Springer-Verlag Berlin Heidelberg; 2014.
Gitajn IL, Toussaint RJ, Kwon JY. Assessing accuracy of sustentaculum screw placement during calcaneal fixation. Foot Ankle Int. 2013;34(2):282-6. doi: 10.1177/1071100712467617.